1 calculate the roof area to be drained.
How to know the number of roof r drains.
Select number of roof drains and calculate the roof area sloped to each drain.
When determining the number roof drains required recognize that the smaller the roof drain outlet diameter the more drains you will need.
Is there a rule of thumb for number of roof drains needed on flat roofs.
A house in chicago has a roof whose actual drainage area is 1 000 square feet.
3 size of leader required.
The flow rate used for sizing the storm drainage piping shall be based on the maximum anticipated ponding at the roof drain.
1 rate of precipitation.
Determine rate of rainfall for this example use 4.
Zurn makes it easy to size roof drains.
The result is the number of drains needed.
A large roof is going to move a lot of water which means the downspout locations may need to be adjust to compensate.
The 6 in 12 pitch factor 1 1 multiplied by 1 000 yields an effective area of 1 100 square feet.
Take the roof s total square footage and divide by the total square footage handled by one drain.
The four things you will need to know are.
6 24 2014 david howard aia said.
When sizing roof drains the limiting factor for the amount of water each drain will carry away is the size of leader therefore increasing.
Gutters come in many sizes.
Each leader must be large enough to handle the volume of water to be drained the greater the leader capacity the fewer roof drains are needed.
2 estimate the roof drain outlet.
2 total area of roof.
If the result is a fraction less use the next higher number.
What is the general area of a flat 1 4 1 0 slope single ply roof for each roof drain ratio for the number of roof drains roof area.
Or 12 drains required.
How to calculate the quantity of drains required.
And 4 area handled by each drain.
Next the roof area is divided by the area for each leader to determine the number of drains required.
The published roof drain flow rate based on the head of water above the roof drain shall be used to size the storm drainage system in accordance with section 1106.
After studying building plan and physical.
A high slope moves water more quickly and if gutters have trouble dealing with a lot of water in a short period of time an extra downspout can alleviate that issue.
Size horizontal storm drainage piping.
Total roof area 500 by 200 100 000 sq.
Using tools from the international plumbing code ipc it s not that hard.
Conversely the larger the drain outlet diameter the fewer you will need.
50 000 4 400 11 36.
Ipc provides four steps to size the roof drains on a building.