Section 1203 attic spaces is defined in chapter 12 interior environment.
Ibc attic definition.
Exterior openings into the attic space of any building intended for human occupancy shall be protected to prevent the entry of birds squirrels rodents snakes and other similar creatures.
Attic section 202 identifies an attic as that space between the ceiling beams at the top story and the roof rafters.
Attic or storyfrom the 2006 ibc commentaryattic.
Unless otherwise required in accordance with the international wildland urban interface code or due to the location of the building within a fire district in accordance with appendix d.
The definition of attic identifies the specific portion of a building or structure for the purposes of determining the applicability of requirements that are specific to at tics such as ventilation see section 1202 and draftstopping see section 716.
In addition there are.
Chapter 9 roof assemblies.
The code official is wrong imo.
The residential code applies to dwellings not more than three stories above grade plane which is what you have plus what appears to be a habitable attic if you chose to use the space as such.
Ibc 1203 2 requires 1 150 th of the attic area to be ventilated but there is an exception that is commonly used instead.
The ibc provides definitions in chapter 2 of terms that are generally used in a number of varied locations throughout the code.
This section states that intake and exhaust vents shall be completed in accordance with section 1203 2 of the ibc.
Openings for ventilation having a least dimension of not less than 1 16 inch 1 6 mm and not more than 1 4 inch 6 4 mm shall be permitted.
The habitable attic was added in the 2009 addition in an attempt to gain bonus space above the 3d floor while remaining in the irc.
The international building code commentary often provides clarification and the intent of code provisions.
Openings for ventilation having a least dimension larger.
2018 international residential code.
On the upcodes website.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
A code provision sometimes overlooked is in the definitions in chapter 2 of the 2015 ibc.
2018 international building code.
Nonclassified roof coverings shall be permitted on buildings of group r 3 and group u occupancies where there is a minimum fire separation distance of 6.
The space between the ceiling beams of the top story and the roof rafters.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
1 foot 304 8 mm 1 square foot 0 0929 m 2.
Exception 1 allows you to only ventilate 1 300 th of the attic area if 50 to 80 of the ventilation occurs at least 3 above eave or cornice vents.